APC-2000/ALW (ALE)

APLISENS
Pressure transmitters
Description
APC-2000/ALW and ALE measure liquid, gas and steam pressure and transmit readings via current output and HART. They feature an aluminium housing, local display and configurable range. Outputs, power supply and explosion protection depend on the version.
Technical features ↓Technical features
Features
- Basic fiducial error limit from 0,05%;
- Measurement ranges: gauge pressure – from 0-0,1 kPa to 0-100 MPa;
- Measurement ranges: absolute pressure – from 0-10 kPa to 0-30 MPa;
- Measurement ranges: compound pressure – from (-0,1)-0,1 kPa to (-0,1)-7,0 MPa;
- Explosion-protected version (only APC-2000/ALW): Ga/GbExiаIICT4/T5/T6 X;
- Explosion-protected version (only APC-2000/ALW): ExdbIICT6/T5/T4;
- Functional safety version SIL2 — APC-2000.Safety/ALW;
- Output signal: 4 - 20 mA + HART;
- Output signal: 0 – 20 mA + HART, 0-5 mA + HART (only APC-2000/ALE);
- Supply voltage: 10 – 55 V (for the general industrial version APC-2000/ALW);
- Supply voltage: 10,5 - 30 V (APC-2000/Ex/ALW);
- Supply voltage: 13,5 - 55 V (APC-2000/Exd/ALW);
- Supply voltage: 15 - 45 V (APC-2000.Safety/ALW)
- Supply voltage: 16 – 28 V (APC-2000.Safety/Ex/ALW)
- Supply voltage: 10 – 36 V for the 4-20 mA output of the general industrial APC-2000/ALE version.
- Version for pressure measurement in oxygen-containing media;
- Digital temperature compensation of additional errors;
- Various process and electrical connections;
- Aluminium housing with display,
- Zero, measurement range and damping adjustment
- Configuration using front-panel buttons without additional devices.
Configuration
- Local configuration buttons beneath the display; no additional devices required;
- КАР-03 communicator;
- HART/USB converter; requires a PC with the supplied Raport software. Wired and Bluetooth versions are available.
Specifications depend on the version. Check the technical documentation for the selected configuration when ordering.
Description and technical data source ↗Documentation
- APC-2000AL PDF ↗
- APC-2000AL SAFETY PDF ↗
- APC-2000ALM PDF ↗
- APC-2000ALW-L PDF ↗
- APC APR PD PZ Ех PDF ↗
- АРС APR ALW Ех PDF ↗
- АРС APR ALW Ехd PDF ↗
- APC APR ALW Safety PDF ↗
- АРС APR ALE PDF ↗
- МП PC PR PDF ↗
- APC-2000ALW PDF ↗
APLISENS UZBEKISTAN
Request a quotation
APC-2000/ALW (ALE)
We can help select the version and connections for your application. Describe your operating conditions when contacting us; specifications for the selected variant are confirmed against the manufacturer’s documentation.