official factory representative in Uzbekistan+998 99 302 33 53+998 77 413 33 53info@aplisens.uz
Aplisens

APR-2000/ALW (APR-2000/ALE)

APLISENS

Differential pressure transmitters

Description

APR-2000/ALW and APR-2000/ALE measure differential pressure in gases, steam and liquids. They have an aluminium housing and display, with current output and HART communication. Permissible static pressure and outputs must be selected for the specific version.

Technical features ↓
Request a quotation →Documentation (10)

Technical features

Features:

  • Basic fiducial error limit from ±0,075%;
  • Measurement ranges: from (-50)-50 kPa, (-2,5)-2,5 kPa to 0-7,0 MPa;
  • Explosion-protected version (only APR-2000/ALW): Ga/GbExiаIICT4/T5/T6 X;
  • Explosion-protected version (only APR-2000/ALW): Ga/GbExiа/dIICT6/T5 X.

Features:

  • Functional safety version SIL2 — APR -2000.Safety/ALW (for version Ех);
  • Output signal: 4 - 20 mA + HART;
  • Output signal: 4 - 20 mA + HART, 0 – 20 mA + HART, 0-5 mA + HART (only APR -2000/ALE);

Features:

  • Supply voltage: 10 – 55 V (for the general industrial version APR-2000/ALW);
  • Supply voltage: 10,5 - 30 V (APR -2000/Ex/ALW);
  • Supply voltage: 13,5 - 55 V (APR -2000/Exd/ALW);
  • Supply voltage: 15 - 45 V (APR -2000.Safety/ALW);
  • Supply voltage: 16 – 28 V (APR -2000.Safety/Ex/ALW);
  • Supply voltage: 10 – 36 V for the 4-20 mA output of the general industrial APR -2000/ALE version.

Features:

  • Linear, reverse and square-root characteristic configuration;
  • Digital temperature compensation of additional errors;
  • Various process and electrical connections;
  • Versions with various diaphragm seals, directly or remotely connected;
  • Version for pressure measurement in chemically aggressive and oxygen-containing media;
  • Aluminium housing with display;
  • Zero, measurement range and damping adjustment;
  • Pressure transmitter configuration using front-panel buttons without additional devices;
  • Optional extended temperature compensation (-60) °C- 50 °C;
  • Output signal settling time 0,5 s;
  • Additional electronic damping 0 - 30 s;
  • Ambient temperature: (-40) - 80 °C for connection type С (or СН); standard temperature compensation: (-25) - 80 °C.

Features:

  • Process temperature: (-50) - 120 °C. Above 120 °C, diaphragm seals or impulse tubes are recommended.

Configuration

  • Local configuration buttons beneath the display; no additional devices required;
  • КАР-03 communicator;
  • HART/USB converter; requires a PC with the supplied Raport software. Wired and Bluetooth versions are available.

Specifications depend on the version. Check the technical documentation for the selected configuration when ordering.

Description and technical data source ↗

Documentation

Manufacturer’s product page ↗